In the field of electrical generation, the Technical Standard for Supervision of Electrical Generation Machines (NTS) plays a crucial role in ensuring the safety and efficiency of systems connected to the grid. This standard is particularly relevant for solar investors, who must meet certain requirements to operate properly. Below, we explain the types of NTS, the powers involved, and clarify common confusion regarding the UGE certificate.
The NTS is divided into different types, each applicable to different power ranges and types of installations:
NTS Type A: It applies to small distributed generation installations, such as residential solar systems. It covers powers typically below 10 kW. These installations must meet basic safety and operational requirements so as not to negatively affect the stability of the grid.
NTS Type B: It is aimed at medium-scale generation facilities, such as commercial or industrial systems. It covers powers from 10 kW to 100 kW. This type includes more stringent requirements for monitoring and control, as well as a more complex integration with network management systems.
NTS Type C: Applicable to large power generation plants, such as industrial-scale solar parks. It covers powers exceeding 100 kW. It requires advanced control and communication systems, as well as robust protection mechanisms and fault response mechanisms.
Solar investors, who convert the energy from solar panels into usable electricity, must comply with the requirements set by the NTS based on their size and capacity. These requirements ensure that the investors operate safely and efficiently, contributing to the stability of the electrical grid.
Investors must have systems in place to protect against overloads, short circuits, and other events that could compromise safety. This includes automatic disconnection mechanisms in the event of abnormal conditions.
The NTS requires the continuous monitoring of investors' performance. They must provide real-time data on their performance, which is essential for effective monitoring and control of the system.
Investors must be able to communicate effectively with the grid control systems, facilitating the coordination and dynamic adjustment of generation according to the needs of the grid.
To comply with the NTS, investors must obtain corresponding certifications such as the LVD, EMC, and NTS Type A, B, or C as applicable. These certifications ensure that the equipment meets all established technical and safety requirements.
Confusion with the UGE Certificate
It is common for users to confuse the UGE certificate (Unit of Electrical Generation) with the requirements of the NTS. Many electric companies request compliance with the NTS, not a UGE certificate. The NTS is the specific regulation that ensures that generating equipment, such as solar inverters, meets the necessary standards to operate on the electrical grid.
To clear up this confusion, it is important to understand that:
· UEG Certificate: It refers to a general accreditation of the generation unit.
· NTS: These are the specific technical standards that establish the operating and safety requirements for the generating machines connected to the grid.
· When your electricity company asks you for a certificate, it is probably referring to compliance with the appropriate NTS for your installation.
The technical standard for the monitoring of electrical generation machines is essential to ensure that solar inverters operate safely and efficiently. Knowing the different types of NTS and their applicable powers is crucial to comply with regulations. Additionally, it is important to clear up the common confusion between the UGE certificate and the NTS requirements to ensure that the installations meet the necessary standards and are approved by the electricity companies.
Edgar Mena,
Product Manager for Renewable Energies at SUNVEC
Contact us for more information or any questions:
Phone numbers: 935 748 206
Tel. SAT Sunvec: 937 617 771
Technical articles
Telecommunications networks and stations: ensuring operation in the event of blackouts with BESS Telecommunications networks are an essential infrastructure, ...
Technical articles
Data centers and BESS: photovoltaic integration and greater operational security Data centers need a continuous, stable and high-quality electrical supply...